Supported
Data Acquisition
- Agilent
34970A
- Fluke
Hydra 2620A, 2625, 2635
- Fluke
2680
- Fluke
NetDAQ 2640, 2645
- TMI
Orion Type 2
- Eurotherm
6 series.
- Eurotherm
5 series.
- Eurotherm/Chessel
4 series.
- TecnoSoft
TempStick & HumiStick
- TQSolutions
Logger
- Yokogawa
MicroR1800
- Anville
800 Series
- Anville
500
- Anville
435
- Anville
425
- Anville
415
- Yokogawa DXP, DX Range
- Kaye
KL/Portable/Digi
- GEKaye
Validator 2000
- MODBUS
- MODBUS
TCP
- Simulation
logger tool for software validation and user Test Specification
validation.
|
|
|
|
Calibration & Calibration Checking
- Select calibration file to store results.
- Select channel groups for calibration
- Allow a test to use sensors calibrated in different groups.
- User managed calibration stability and set point profile.
- Automatic calibration option with automated stability analysis procedure.
- Calibration progress monitor window with adjustable reference temperature for manual calibration.
- Abort option.
- Detailed comprehensive calibration reports stored & archived with management window.
- Automatic management of calibration files. Test records are automatically assigned all relevant calibration reports for sensors used.
- Out of specification channels highlighted and when used in a test automatically set to defective.
- Automatic management of calibration checking files. Test records are automatically assigned all relevant check reports for sensors used.
|
|
|
Test Specifications
Allow user to create unlimited Test Specification files.
- Allow new file to start with copy of existing one.
- General Settings tab allows selection of
- channel configuration file
- calibration file
- sterilization/disinfection temp.
- scan interval
- automatic stop options
- stage analysis (for HTM2010)
- continuous monitoring options
- selection of time format
- chart configuration
- data list configuration
- Calculations tab allows setup of calculations based on each row of data
- Max per scan
- Min per scan
- Average per scan
- Max-Min per scan
- Max – Average per scan
- Average – Min per scan
- Min Lethality per scan
- Saturation temperature
- Saturation pressure
- Lethality tab allows configuration of lethality calculations
- Base temperature & Z value
- Probe group.
- Start lethality on temperature or stage.
- End lethality on stage.
- Temperature/Pressure correlation limit with reset option.
- Option to use lethality config on time at temperature calculations.
- Probe selection allowing location entry.
- Setup of stages for manual entry during the test.
- Setup of parameter specific to logger selected (eg TMI-ORION)
- Test Specification file is copied to test record for access historically as Test Detail.
- Historic changes do not affect Test Specifications on Setup menu.
- Test records have Test Setup report of Test Specification parameters.
- Historic tests can be re-analysed after fully audited changes to historic test specification.
- Channels can be set or unset to or from defective state.
- Channels set as defective are not reported or included in any calculations
|
|
|
|
The Chart
- Chart is fully configurable.
- Setup margins for printout.
- Setup range for each unit.
- Setup number of grid lines.
- Setup trace thickness.
- Real time chart all functions operational.
- Displays stages and I-Calc actions.
- Shows two vertical axis ranges, one temperature, the other non temperature (any units).
- Chart can be dragged & resized.
- Chart displays trace ID at customizable interval.
- Mouse pointer on chart shows values & time value at location.
- Data line option shows values & time at sliding line.
- Easy stage entry option at data line position.
- Zoom into any area and the zoom in again.
- Chart printout includes trace ID table.
|
|
|
|
Historical Test Storage & Retrieval
- All tests are stored in separate machine folders.
- Each test has entry in Historic Test Index.
- Test Index refresh option scans specified folder and all sub-folders for stored tests and creates new list.
- Historic Test List can be configured to show any number of test data fields.
- List can be filtered and sorted on date and time.
- List can be configured for ‘tree view’ mode to group tests according to any field (eg hospital site).
- Next and previous buttons sequences through tests updating the chart window with next record.
|
|
|
|
Company Name & System ID & Options
- User name heading all reports.
- Configuration file ID tag for group users.
- Selectable date format.
|
|
|
|
Calibration Files
- Allows multiple calibration files selected on user managed names.
- Option to switch off calibration.
- Select from names for calibration function.
- Contains last calibrated date, time, pass/fail etc details for each channel.
|
|
|
|
Test Equipment Database
Store all information on Test Equipment in database allowing selectable serial numbers.
- Test equipment information automatically copied to calibration reports.
- Fields can be used in SVR Custom Forms.
|
|
|
|
Real Time Display
- Real time display window shows all values as soon as received from logger.
- Includes time above temperature, lethality, correlation etc.
- Shows time elapsed, current stage, elapsed stage time.
|
|
|
|
The Stages Window
- Stages window allows editing of file containing all possible stages, test specification stage list, or test record stage list.
- Allows alteration of ‘interval’ setting for each stage.
- Allows stages to be added from list of all possible stages.
- Allows stages to be removed.
- Allows user to manually enter the times of stages.
- In real time mode allows the next stage in the test specification list to be manually added.
|
|
|
 |
 |
 |
 |
|
Supported Calibration Baths
- ISOTECH
Range
- GEKaye
HTR400
- ASL
B Series Metal Block Calibrator
- Isotech
Calisto 2140B
- GEKaye
LTR/HTR
- HART
Micro 6102, 7102, 7103
- HART
7380
- Jofra
ATC
- Fluke
917X Series
|
|
|
|
Supported Temperature Reference Devices
- HART/FLUKE
1502A & Compatible
- ISOTECH
TTI6
- Kaye
Intelligent RTD
- Kaye
HTR400/LTR140 Controller
- ASL
F250 MkII Precision Thermometer
- Isotech
Calisto INDICATOR
- Isotech
Calisto Controller
- ASL
B Series Calibrator Controller
- Anville
Series 270 Digital Thermometer
- Cropico
3001
- HART
Micro 6102, 7102, 7103 Controller
- HART
7380 Controller
- AMETEK
DTI
|
|
|
|
Security & 21 CFRpart 11
- Login window with ID & password.
- Password timeout & Renew.
- Electronic Signatures on Reports.
- Security Data is encrypted.
- Complete Audit Trail detailing Change History.
- Complete Audit Archive & Retrieve Changes Option.
- Security Management Window.
- Operator Profile Management.
- Operator Timeout & Password length & timeout Controls.
- Data Files Tamper Proofing.
|
|
|
|
Test
Specifications I-Calcs
User configurable Interval Calculations
- User managed list window.
- Allow I-Calc duplication.
- Allow I-Calc copy to another Test Specification.
- Select purpose of I-Calc
- Chart line
- Stage or message insert.
- Continuous limit monitoring.
- Calculation on Interval
- Select group of probes
- Calculations available
- Selectable groups
- Selectable Interval
- Selectable Limits
- Set IO on Limit
- Set Message on Limit
- Set Report colour on Limit
- Select where calculation appears
- Set insert stage event on Limit.
- Interval Duration.
- Time at Temperature.
- Max probe value.
- Min of Maxs.
- (Max - Min) Of Maxs.
- Min probe value.
- Max of Mins.
- (Max - Min) Of Mins
- Average probe value.
- Max Average.
- Min Average.
- Fluctuation.
- Max Fluctuation
- Max Deviation.
- Max lethality.
- Min lethality.
- Lethality Deviation.
- Allow entry of limit values.
- Target value
- Upper limit.
- Lower limit.
- Hysteresis
- Allow entry of actions
- Message to show on chart and/or data list.
- Insert message at offset from actual time I-Calc is triggered.
- Highlight on failure.
- Hide on chart or data list option.
- Digital IO ON/OFF.
- Display screen message.
|
|
|
|
The Data List
- Highly detailed and configurable Data Listing option.
- Displays stages and I-Calc actions & results.
- Summary option allows data to be printed at intervals configured for each stage.
- Data List can be dragged & resized.
- Landscape or portrait option.
- Prints data in configurable colors according to value.
- If too many channels for one line, data is formatted to fit paper.
- All calculations can be shown.
- Electronic signature option
|
|
|
|
Data Management & Archiving
- Data Management window
- Allows selection of multiple Tests, Calibration records, Calibration Check records, or user configuration files.
- For user configuration files user can further select the type of files.
- Report on space requirement.
- Allows selection of drive or network location for copy target.
- Stores an ID on the target.
- Reports space available on target.
- Allows selected files to be copied and or deleted.
- Archive window allows
- Target drive or network location selection.
- Automatic archiving option at end of test or calibration.
- Real time archiving as test is being logged.
- Start button for archive process.
- Shows progress of archive process.
- When archiving only changed or new files are transferred.
|
|
|
|
Machine Records Database
- User managed database of equipment or facilities tested with custom fields.
- Select machine for each test.
- Information automatically copied to test records.
- Fields can be used in SVR Custom Forms.
- Filter records.
|
|
|
|
Channel Configurations
- Allows multiple channel configurations selected on user managed names.
- Automatically configures most loggers.
- Select Input Type.
- Select Chart Colour.
- Select Units, Decimal Places.
- User managed channel names.
|
|
|
|
Running a Test
- Selection of Test Specification.
- Entry of Job reference.
- Entry of cycle number.
- Selection of machine or facility being tested.
- Custom entries are available.
- Most application functions available while test is logging.
- Or multiple TQS programs can be run from same folder, one logging a test, the other being used to create reports.
|
|
|
|
The Test Merge Feature
- Data from different kinds of logger can be merged into a new test record.
- Specify how time differences are handled.
- Specify a Test Specification to use for the new merged test record.
- Select data from any number of tests and select specific channels to merge.
- Auto selection feature on matching sensor locations.
|
|